| Steel Screening (High Performance)
The best possible performance figures coupled with low maintenance and long design life are all incorporated in a fully seam welded steel screened chamber.
This type of screening is used on larger projects in preference to modular screening. Stand alone EMC test facilities are a prime example when higher attenuation coupled with maximum design life is required. This type of screening offers greater structurally capability for supporting plant, anechoic or ferrite linings, large doors and a variety of other components.
Typical Performance Characteristics
| Magnetic Field |
› 60dB 10KHz - 100dB - 100KHz |
| Electric Field |
› 100dB 1KHz - 1GHz |
| Plane Wave |
› 100dB 1GHz - 10GHz |
*Maximum performance is governed by material thickness, number and type of penetrations.
|